Product
Time to move toward clean air, we will introduce the products of the Korea Fine Dust Research Institute. PRODUCTElectrical heat exchangerAs a ventilation device for forced supply and exhaust heat recovery without a separate heating or cooling source, the energy in the air discharged during ventilation is introduced. It is the most ideal ventilation system that maintains indoor temperature and humidity by delivering it to the outside air.
ACT-B100RC | ACT-B150RC | ACT-B200RC | |
---|---|---|---|
Air volume(CMH) | 100(Very strong) / 100(Strong) / 60(Weak) | 150(Very strong) / 150(Strong) / 90(Weak) | 200(Very strong) / 200(Strong) / 140(Weak) |
Power consumption(W) | 38(Very strong) / 35.4(Strong) / 28(Weak) | 60(Very strong) / 56.7(Strong) / 40(Weak) | 70(Very strong) / 63(Strong) / 55(Weak) |
Product size | 610 X 580 X 330(H) mm | 610 X 580 X 330(H) mm | 610 * 580 * 330(H) mm |
Weight | 12kg | 12kg | 12kg |
MD (6EA) | SA, RA, EA, OA | SA, RA, EA, OA | SA, RA, EA, OA |
Connection duct | Ø125 | Ø125 | Ø125 |
Filter | pre-filter, 50T HEPA filter (H13) | pre-filter, 50T HEPA filter (H13) | pre-filter, 50T HEPA filter (H13) |
Controller | Fine dust/CO2 integrated room controller | Fine dust/CO2 integrated room controller | Fine dust/CO2 integrated room controller |
Others | Optional options for bypass and clean internal circulation functions |
Large capacity electrical heat exchangerAs a ventilation device suitable for use in a large space requiring electrical heat, the basic function is the same, and it is an ideal large-capacity ventilation system that maintains the indoor temperature and humidity according to the size of the space.
ACT- C500HEG | ACT- C800HEG | ACT- C1000HEG | |
---|---|---|---|
Air volume(CMH) | 500(Very strong) / 500(Strong) / 250(Weak) | 800(Very strong) / 800(Strong) / 350(Weak) | 1000(Very strong) / 1000(Strong) / 420(Weak) |
Power consumption(W) | 201(Very strong) / 196(Strong) / 175(Weak) | 354(Very strong) / 348(Strong) / 310(Weak) | 363(Very strong) / 355(Strong) / 325(Weak) |
Product size | 974 X 602 X 474(H) | 1122 X 1178 X 474(H) | 1122 X 1178 X 474(H) |
Weight | 42kg | 65kg | 65kg |
MD (6EA) | SA, RA, EA, OA | SA, RA, EA, OA | SA, RA, EA, OA |
Connection duct | Ø200 x 2 | Ø250 x 2 | Ø250 x 2 |
Filter | pre-filter, 50T HEPA filter (H13) | pre-filter, 50T HEPA filter (H13) | pre-filter, 50T HEPA filter (H13) |
Controller | Fine dust/CO2 integrated room controller | Fine dust/CO2 integrated room controller | Fine dust/CO2 integrated room controller |
Others | Optional options for bypass and clean internal circulation functions |